. Calibration: Type K/KX, J/JX, E/EX, T/TX, N/NX, RX and SX
. Conductor: Solid or stranded
. No. of pair: Single
. Insulation: Braided fiberglass with silicon varnish coated
. Construction: Twisted conductors
. Tolerance: Standard limits of error and special limits of error
. Max. operating temperature: 480°C
. Color code: ANSI, IEC, JIS, DIN, BS, NFC
Quantity:
  • KX-FB-TW-20

  • ZONZEN

  • 8544491900

Feature

Fiberglass insulated twisted pair thermocouple wire and thermocouple extension wire - Single pair

. Continuous use up to 480°C
. Short term use up to 537°C
. Flexible with good moisture, chemical and abrasion resistance
. Provides accurate temperature measure with high temperature stablility
. Calibration test report is available

Twisted pair thermocouple extension wire physical properties
Characteristics Insulation
Abrasion Resistance Good
Cut Through Resistance Very good
Moisture Resistance Good
Solvent Resistance Excellent
Service Temperature

480°C continuous

537°C single
Flame Test Non-flammable

Specification

Item Specification
Calibration Type J/JX Type K/KX Type T/TX Type E/EX Type N/NX Type RX/SX Type BX
+ Iron
- Constantan
+ Chromel
- Alumel
+ Copper
- Constantan
+ Chromel
- Constantan
+ Nirosil
- Nisil
+ Copper
- Alloy 11
+ Copper-S
- Copper-E
Wire size 12, 14, 16, 18, 20, 24, 26, 28, 30, 32AWG
Conductor Solid or Stranded
Construction Twisted conductors
Number of pair Single
Insulation Braided fiberglass with silicon varnish
Tolerance Standard limits of error or special limits of error
Max. Operating temperature 480°C
Color code ANSI, IEC, JIS, DIN, BS, NFC
Packing Roll or spool (As required)

Order code

Model explantion:
QQ截图20160415104020

1. Calibration: Type K/KX, J/JX, T/TX, E/EX, N/NX, RX/SX, BX
2. Insulation: Fibergalss
3. "TW" means twisted
4. Wire size (AWG)
5. "S" means "Stranded", "Blank" means "Solid"

Order code:

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Extension wire

12  1/1.78 Solid JX-FB-TW-12 KX-FB-TW-12 TX-FB-TW-12 EX-FB-TW-12
12 7/20 7/0.67 Stranded JX-FB-TW-12S KX-FB-TW-12S TX-FB-TW-12S EX-FB-TW-12S
14 1/1.63 Solid JX-FB-TW-14 KX-FB-TW-14 TX-FB-TW-14 EX-FB-TW-14
14 7/22 7/0.635 Stranded JX-FB-TW-14S KX-FB-TW-14S TX-FB-TW-14S EX-FB-TW-14S

16

1/1.29

Solid

JX-FB-TW-16

KX-FB-TW-16

TX-FB-TW-16

EX-FB-TW-16

16 7/24 7/0.50 Stranded JX-FB-TW-16S KX-FB-TW-16S TX-FB-TW-16S EX-FB-TW-16S

20

1/0.80

Solid

JX-FB-TW-20

KX-FB-TW-20

TX-FB-TW-20

EX-FB-TW-20

20 7/28

7/0.30

Stranded

JX-FB-TW-20S

KX-FB-TW-20S

TX-FB-TW-20S

EX-FB-TW-20S

24

1/0.50

Solid

JX-FB-TW-24

KX-FB-TW-24

TX-FB-TW-24

EX-FB-TW-24

24 7/32

7/0.20

Stranded

JX-FB-TW-24S

KX-FB-TW-24S

TX-FB-TW-24S

EX-FB-TW-24S

26 1/0.40 Solid JX-FB-TW-26 KX-FB-TW-26 TX-FB-TW-26 EX-FB-TW-26
26 7/34 7/0.16 Stranded JX-FB-TW-26S KX-FB-TW-26S TX-FB-TW-26S EX-FB-TW-26S
28 1/0.32 Solid JX-FB-TW-28 KX-FB-TW-28 TX-FB-TW-28 EX-FB-TW-28
28 7/36 7/0.13 Stranded JX-FB-TW-28S KX-FB-TW-28S TX-FB-TW-28S EX-FB-TW-28S
30 1/0.25 Solid JX-FB-TW-30 KX-FB-TW-30 TX-FB-TW-30 EX-FB-TW-30
32 1/0.20 Solid JX-FB-TW-32 KX-FB-TW-32 TX-FB-TW-32 EX-FB-TW-32

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Thermocouple wire

12  1/1.78 Solid J-FB-TW-12 K-FB-TW-12 T-FB-TW-12 E-FB-TW-12
12 7/20 7/0.67 Stranded J-FB-TW-12S K-FB-TW-12S T-FB-TW-12S E-FB-TW-12S
14 1/1.63 Solid J-FB-TW-14 K-FB-TW-14 T-FB-TW-14 E-FB-TW-14
14 7/22 7/0.635 Stranded J-FB-TW-14S K-FB-TW-14S T-FB-TW-14S E-FB-TW-14S

16

1/1.29

Solid

J-FB-TW-16

K-FB-TW-16

T-FB-TW-16

E-FB-TW-16

16 7/24 7/0.50 Stranded J-FB-TW-16S K-FB-TW-16S T-FB-TW-16S E-FB-TW-16S

20

1/0.80

Solid

J-FB-TW-20

K-FB-TW-20

T-FB-TW-20

E-FB-TW-20

20 7/28

7/0.30

Stranded

J-FB-TW-20S

K-FB-TW-20S

T-FB-TW-20S

E-FB-TW-20S

24

1/0.50

Solid

J-FB-TW-24

K-FB-TW-24

T-FB-TW-24

E-FB-TW-24

24 7/32

7/0.20

Stranded

J-FB-TW-24S

K-FB-TW-24S

T-FB-TW-24S

E-FB-TW-24S

26 1/0.40 Solid J-FB-TW-26 K-FB-TW-26 T-FB-TW-26 E-FB-TW-26
26 7/34 7/0.16 Stranded J-FB-TW-26S K-FB-TW-26S T-FB-TW-26S E-FB-TW-26S
28 1/0.32 Solid J-FB-TW-28 K-FB-TW-28 T-FB-TW-28 E-FB-TW-28
28 7/36 7/0.13 Stranded J-FB-TW-28S K-FB-TW-28S T-FB-TW-28S E-FB-TW-28S
30 1/0.25 Solid J-FB-TW-30 K-FB-TW-30 T-FB-TW-30 E-FB-TW-30
32 1/0.20 Solid J-FB-TW-32 K-FB-TW-32 T-FB-TW-32 E-FB-TW-32
 

Note: The products referenced above represent the most popular constructions. Other constructions can be manufactured to meet individual specification and application requirements.

Techinal Data

Color Code & Initial Calibration Tolerance for Thermocouple Extension Wire:

Thermocouple extension type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron (+) vs.  Constantan(-)

JX

White/Red

Black

0°C to +200°C

± 2.2°C

± 1.1°C

Chromel (+) vs.  Alumel (-)

KX

Yellow/Red

Yellow

0°C to +200°C

± 2.2°C

± 1.1°C

Copper(+) vs. Constantan(-)

TX

Blue/Red

Blue

-60°C to +100°C

± 1.1°C

± 0.5°C

Chromel(+) vs. Constantan(-)

EX

Purple/Red

Purple

0°C to +200°C

± 1.7°C

± 1.1°C

Nirosil (+) vs. Nisil (-) NX Orange/Red Orange 0°C to +200°C ± 2.2°C ± 1.1°C
Copper (+) vs. Alloy 11 (-) RX/SX Black/Red Green 0°C to +200°C ± 5°C -
Copper S (+) vs. -Copper E (-) BX Gray/Red Gray 0°C to +200°C ± 3.7°C -
Color Code & Initial Calibration Tolerance for Thermocouple Wire:

Thermocouple type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron(+) vs.
Constantan(-)

J

White/Red

Brown

0°C to +285°C
285°C to +750°C

± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

CHROMEL(+) vs.
ALUMEL(-)

K

Yellow/Red

Brown

-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C

± 2%
± 2.2°C
± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

Copper(+) vs.
Constantan(-)

T

Blue/Red

Brown

-200°C to -65°C
-65°C to +130°C
130°C to +350°C

± 1.5%
± 1°C
± 0.75%

± 0.8%
± 0.5°C
± 0.4%

CHROMEL(+) vs.
Constantan(-)

E

Purple/Red

Brown

-200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C

± 1%
± 1.7°C
± 1.7°C
± 0.5%

± 1°C
± 1°C
± 0.4%
± 0.4%

Nominal Insulation Thickness:

Wire Size (AWG)

Conductor Insulation Thickness (mm)

14

0.25

16

0.25

16 7/24

0.25

20

0.20

20 7/28

0.20

24

0.20

24 7/32

0.20

26 0.20
28 0.20
30 0.20

Previous: 
Next: 
Feedback

Navigations

Product Categories

Contact Us

   +86-577-61731117
   +86-577-61731116
   +86-13868772123
   +86-13868772123

Get In Touch

Check our privacy policy on how we collect and process your information.
Copyright 2022 © Zhejiang Zonzen Electric Co., Ltd. All Rights Reserved. Sitemap. Privacy Policy