Fiberglass insulated parallel construction thermocouple wire and thermocouple extension wire with metal overbraid - Single pair

. Calibration: Type K/KX, J/JX, E/EX, T/TX, N/NX and RX, SX
. Wire type: Solid or Stranded
. No. of pairs: 1
. Construction configuration: Parallel
. Insulation: Braided fiberglass with silicon varnished
. Overall jacket: Braided fiberglass with silicon varnished
. Overbraid: Stainless steel or tinned copper braided
. Tolerance: standard limits & special Limits of Error
. Max. Operating Temperature: 480°C
. Color Code: ANSI, IEC, JIS, DIN, BS, NFC
Quantity:
  • KX-FB-FB-SSB-24S

  • ZONZEN

  • 8544491900

Feature

Fiberglass insulated parallel construction thermocouple wire and thermocouple extension wire with metal overbraid - Single pair

. Continuous use up to 480°C
. Short term use up to 537°C
. Flexible with good moisture, chemical and abrasion resistance
. Provides accurate temperature measure with high temperature stablility
. Calibration test report is available

FB-FB Physical Properties
Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Very good Excellent
Moisture Resistance Good Good
Solvent Resistance Excellent Excellent
Service Temperature

480°C continuous

537°C single

480°C continuous

537°C single

Flame Test Non-flammable Non-flammable

Specification

Item Specification
Calibration Type J/JX Type K/KX Type T/TX Type E/EX Type N/NX Type RX/SX Type BX
+ Iron
- Constantan
+ Chromel
- Alumel
+ Copper
- Constantan
+ Chromel
- Constantan
+ Nirosil
- Nisil
+ Copper
- Alloy 11
+ Copper-S
- Copper-E
Wire Size 12, 14, 16, 18, 20, 24, 26, 28, 30, 32AWG
Wire Type Solid or Stranded
Conductor Configuration Parallel 
Number of Pairs 1
Insulation Braided Fiberglass With Silicon Varnished
Overall Jacket Braided Fiberglass With Silicon Varnished
Overbraid Stainless Steel Braided or Tinned Copper Braided
Tolerance Standard Limits of Error or Special Limits of Error
Max. Operating Temperature 480°C
Color Code ANSI, IEC, JIS, DIN, BS, NFC
Packing Roll or on Spool (As required)

Order code

Model explanation

1  Calibration: K/KX, J/JX, T/TX, E/EX, N/NX, SX, RX
2  Insulation: Braided Glass Fiber
3  Inner shield: Stainless steel braiding
4  Jacket: Braided Glass Fiber
5  Outer shield: Stainless steel braiding
6  Wire size: 12, 14, 16, 18, 20, 24, 26, 28, 30, 32AWG
7  "S" means "Stranded"; "Blank" means "Solid"

Order code:

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Extension wire

12  1/1.78 Solid JX-FB-FB-SSB-12 KX-FB-FB-SSB-12 TX-FB-FB-SSB-12 EX-FB-FB-SSB-12
12 7/20 7/0.67 Stranded JX-FB-FB-SSB-12S KX-FB-FB-SSB-12S TX-FB-FB-SSB-12S EX-FB-FB-SSB-12S
14 1/1.63 Solid JX-FB-FB-SSB-14 KX-FB-FB-SSB-14 TX-FB-FB-SSB-14 EX-FB-FB-SSB-14
14 7/22 7/0.635 Stranded JX-FB-FB-SSB-14S KX-FB-FB-SSB-14S TX-FB-FB-SSB-14S EX-FB-FB-SSB-14S

16

1/1.29

Solid

JX-FB-FB-SSB-16

KX-FB-FB-SSB-16

TX-FB-FB--SSB-16

EX-FB-FB-SSB-16

16 7/24 7/0.50 Stranded JX-FB-FB-SSB-16S KX-FB-FB-SSB-16S TX-FB-FB-SSB-16S EX-FB-FB-SSB-16S

20

1/0.80

Solid

JX-FB-FB-SSB-20

KX-FB-FB-SSB-20

TX-FB-FB-SSB-20

EX-FB-FB-SSB-20

20 7/28

7/0.30

Stranded

JX-FB-FB-SSB-20S

KX-FB-FB-SSB-20S

TX-FB-FB-SSB-20S

EX-FB-FB-SSB-20S

24

1/0.50

Solid

JX-FB-FB-SSB-24

KX-FB-FB-SSB-24

TX-FB-FB-SSB-24

EX-FB-FB-SSB-24

24 7/32

7/0.20

Stranded

JX-FB-FB-SSB-24S

KX-FB-FB-SSB-24S

TX-FB-FB-SSB-24S

EX-FB-FB-SSB-24S

26 1/0.40 Solid JX-FB-FB-SSB-26 KX-FB-FB-SSB-26 TX-FB-FB-SSB-26 EX-FB-FB-SSB-26
26 7/34 7/0.16 Stranded JX-FB-FB-SSB-26S KX-FB-FB-SSB-26S TX-FB-FB-SSB-26S EX-FB-FB-SSB-26S
28 1/0.32 Solid JX-FB-FB-SSB-28 KX-FB-FB-SSB-28 TX-FB-FB-SSB-28 EX-FB-FB-SSB-28
28 7/36 7/0.13 Stranded JX-FB-FB-SSB-28S KX-FB-FB-SSB-28S TX-FB-FB-SSB-28S EX-FB-FB-SSB-28S
30 1/0.25 Solid JX-FB-FB-SSB-30 KX-FB-FB-SSB-30 TX-FB-FB-SSB-30 EX-FB-FB-SSB-30
32 1/0.20 Solid JX-FB-FB-SSB-32 KX-FB-FB-SSB-32 TX-FB-FB-SSB-32 EX-FB-FB-SSB-32

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Thermocouple wire

12  1/1.78 Solid J-FB-FB-SSB-12 K-FB-FB-SSB-12 T-FB-FB-SSB-12 E-FB-FB-SSB-12
12 7/20 7/0.67 Stranded J-FB-FB-SSB-12S K-FB-FB-SSB-12S T-FB-FB-SSB-12S E-FB-FB-SSB-12S
14 1/1.63 Solid J-FB-FB-SSB-14 K-FB-FB-SSB-14 T-FB-FB-SSB-14 E-FB-FB-SSB-14
14 7/22 7/0.635 Stranded J-FB-FB-SSB-14S K-FB-FB-SSB-14S T-FB-FB-SSB-14S E-FB-FB-SSB-14S

16

1/1.29

Solid

J-FB-FB-SSB-16

K-FB-FB-SSB-16

T-FB-FB--SSB-16

E-FB-FB-SSB-16

16 7/24 7/0.50 Stranded J-FB-FB-SSB-16S K-FB-FB-SSB-16S T-FB-FB-SSB-16S E-FB-FB-SSB-16S

20

1/0.80

Solid

J-FB-FB-SSB-20

K-FB-FB-SSB-20

T-FB-FB-SSB-20

E-FB-FB-SSB-20

20 7/28

7/0.30

Stranded

J-FB-FB-SSB-20S

K-FB-FB-SSB-20S

T-FB-FB-SSB-20S

E-FB-FB-SSB-20S

24

1/0.50

Solid

J-FB-FB-SSB-24

K-FB-FB-SSB-24

T-FB-FB-SSB-24

E-FB-FB-SSB-24

24 7/32

7/0.20

Stranded

J-FB-FB-SSB-24S

K-FB-FB-SSB-24S

T-FB-FB-SSB-24S

E-FB-FB-SSB-24S

26 1/0.40 Solid J-FB-FB-SSB-26 K-FB-FB-SSB-26 T-FB-FB-SSB-26 E-FB-FB-SSB-26
26 7/34 7/0.16 Stranded J-FB-FB-SSB-26S K-FB-FB-SSB-26S T-FB-FB-SSB-26S E-FB-FB-SSB-26S
28 1/0.32 Solid J-FB-FB-SSB-28 K-FB-FB-SSB-28 T-FB-FB-SSB-28 E-FB-FB-SSB-28
28 7/36 7/0.13 Stranded J-FB-FB-SSB-28S K-FB-FB-SSB-28S T-FB-FB-SSB-28S E-FB-FB-SSB-28S
30 1/0.25 Solid J-FB-FB-SSB-30 K-FB-FB-SSB-30 T-FB-FB-SSB-30 E-FB-FB-SSB-30
32 1/0.20 Solid J-FB-FB-SSB-32 K-FB-FB-SSB-32 T-FB-FB-SSB-32 E-FB-FB-SSB-32
 

Note: The products referenced above represent the most popular constructions. Other constructions can be manufactured to meet individual specification and application requirements.

 
Inner shield 
All above thermocouple wire and extension wire can be finished with a inner shield (Stainless steel-SSB, Tinned copper-TCB). If you need the wire with a inner shield, please add "SSB or TCB" to the order code, such as "JX-FB-SSB-FB-20S", it means Type JX, 20AWG, Stranded, Insulation: Fiberglass, Inner shield: Stainless steel, Jacket: Fiberglass 

Outer shield 
All above thermocouple wire and extension wire also can be finished with a metal outer shield to give added protection from abrasion and mechanical damage. If you need the wire with a outer shield, please add "SSB or TCB" to the order code, such as "JX-FB-FB-SSB-20S", it means Type JX, 20AWG, Stranded, Insulation: Fiberglass, Jacket: Fiberglass, Outer shield: Stainless steel 

Technical Data

Color Code & Initial Calibration Tolerance for Thermocouple Extension Wire:

Thermocouple extension type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron (+) vs.  Constantan(-)

JX

White/Red

Black

0°C to +200°C

± 2.2°C

± 1.1°C

Chromel (+) vs.  Alumel (-)

KX

Yellow/Red

Yellow

0°C to +200°C

± 2.2°C

± 1.1°C

Copper(+) vs. Constantan(-)

TX

Blue/Red

Blue

-60°C to +100°C

± 1.1°C

± 0.5°C

Chromel(+) vs. Constantan(-)

EX

Purple/Red

Purple

0°C to +200°C

± 1.7°C

± 1.1°C

Nirosil (+) vs. Nisil (-) NX Orange/Red Orange 0°C to +200°C ± 2.2°C ± 1.1°C
Copper (+) vs. Alloy 11 (-) RX/SX Black/Red Green 0°C to +200°C ± 5°C -
Copper S (+) vs. -Copper E (-) BX Gray/Red Gray 0°C to +200°C ± 3.7°C -
Color Code & Initial Calibration Tolerance for Thermocouple Wire:

Thermocouple type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron(+) vs.
Constantan(-)

J

White/Red

Brown

0°C to +285°C
285°C to +750°C

± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

CHROMEL(+) vs.
ALUMEL(-)

K

Yellow/Red

Brown

-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C

± 2%
± 2.2°C
± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

Copper(+) vs.
Constantan(-)

T

Blue/Red

Brown

-200°C to -65°C
-65°C to +130°C
130°C to +350°C

± 1.5%
± 1°C
± 0.75%

± 0.8%
± 0.5°C
± 0.4%

CHROMEL(+) vs.
Constantan(-)

E

Purple/Red

Brown

-200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C

± 1%
± 1.7°C
± 1.7°C
± 0.5%

± 1°C
± 1°C
± 0.4%
± 0.4%

 
Nominal Insulation Thickness:

Wire Size (AWG)

Conductor Insulation Thickness (mm)

Jacket Insulation Thickness (mm)

Outer Diameter (mm)

14

0.18

0.25

2.5 X4.6

16

0.18

0.25

2.2X3.8

16 7/24

0.18

0.25

2.4X4.3

20

0.15

0.15

1.4X2.5

20 7/28

0.15

0.15

1.5X2.7

24

0.15

0.15

1.0X1.7

24 7/32

0.15

0.15

1.2X2.1

26 0.11 0.15 0.9X1.5
28 0.11 0.15 0.8X1.4
30 0.11 0.15 0.8X1.2

Previous: 
Next: 
Feedback

Navigations

Product Categories

Contact Us

   +86-577-61731117
   +86-577-61731116
   +86-13868772123
   +86-13868772123

Get In Touch

Check our privacy policy on how we collect and process your information.
Copyright 2022 © Zhejiang Zonzen Electric Co., Ltd. All Rights Reserved. Sitemap. Privacy Policy