You are here: Home » Solid State Relay » DC solid state relay » VDR series 10~120Amps DC to DC SSR solid state relay

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

VDR series 10~120Amps DC to DC SSR solid state relay

·Optical isolation between input and output circuits.
·Control signal and TTL logic interface.
·Transistor output,small on-state voltage drop,fast switching speed.
·LEDs indicate the working status.
·Epoxy resin encapsulation integrated, anti-corrosion and shock-proof, reliable work.
Availability:
Quantity:
  • VDR

  • ZONZEN

Product Description

DC solid state relay is mainly used in industrial automation, isolated control of weak current and strong current and various high-power DC electrical equipment, such as DC motors, solenoid valves, electromagnetic vibrators, batteries charge and discharge switch etc.

Ordering options

Model

1. VDR: DC solid state relays
2. Load current: 10: 10Amps, 25: 25Amps, 40: 40Amps, 60: 60Amps, 80: 80Amps, 100: 100Amps, 120: 120Amps
3. Control voltage: D: 3~32VDC 
4. Output voltage: D06: 12~60VDC, D08: 12~80VDC, D12: 12~120VDC, D25: 12~250VDC, D40: 12~400VDC, D60: 12~600VDC, D90: 12~900VDC, D120: 12~1200VDC

Product Selection

Control

Voltage

Output

Voltage

Rated Operational Current



10Amps

25Amps

40Amps

60Amps

80Amps

100Amps

120Amps

3 to 32VDC

60VDC

VDR10DD06

VDR25DD06

VDR40DD06

VDR60DD06

VDR80DD06

VDR100DD06

VDR120DD06

3 to 32VDC

80VDC

VDR10DD08

VDR25DD08

VDR40DD08

VDR60DD08

VDR80DD08

VDR100DD08

VDR120DD08

3 to 32VDC

120VDC

VDR10DD12

VDR25DD12

VDR40DD12

VDR60DD12

VDR80DD12

VDR100DD12

VDR120DD12

3 to 32VDC

250VDC

VDR10DD25

VDR25DD25

VDR40DD25

VDR60DD25

VDR80DD25

VDR100DD25

VDR120DD25

3 to 32VDC

400VDC

VDR10DD40

VDR25DD40

VDR40DD40

VDR60DD40

VDR80DD40

VDR100DD40

VDR120DD40

3 to 32VDC

600VDC

VDR10DD60

VDR25DD60

VDR40DD60

VDR60DD60

VDR80DD60

VDR100DD60

VDR120DD60

3 to 32VDC

900VDC

VDR10DD90

VDR25DD90

VDR40DD90

VDR60DD90

VDR80DD90

VDR100DD90

VDR120DD90

3 to 32VDC

1200VDC

VDR10DD120

VDR25DD120

VDR40DD120

VDR60DD120

VDR80DD120

VDR100DD120

VDR120DD120


Technical Parameter

Input

Parameter-list

Specification Limits

Input Parameter

D

Control Voltage Range

3 to 32VDC

nput Current [Max.]

4-30mA

Must Turn-on Voltage

3VDC

Must Turn-off Voltage

1VDC

Reverse Voltage [Max.]

-6VDC

Output 

Units

Specification Limits

Load current

Amps

10

25

40

60

80

100

120

Load Current Range

ArmS

0.05 to 10

0.05 to 25

0.05 to 40

0.1 to 60

0.1 to 80

0.1 to 100

0.1 to 120

Surge Current 10mSec [Max.]

Arms

200%

Load Voltage Range

Vrms

60VDC~1200VDC

On-state Voltage drop

Vrms

≤0.5~4.6

nff-state Voltage

Vrms

60V,80V,250V,400V600V,≥900V,1200V

Overvoltage Protection

Transient protection voltage are :80V,180V,470V,1000V

Switching Characteristics

Mos or IGBT-solid-state non-contact switching characteristics

General Specifications [Ta=25°C]

Description

10A

25A

40A

60A

80A

100A

120A

Dielectric Strength,Input to Output [50/60 Hz]

2500Vrms

Dielectric Strength,Input/Output to Base [50/60 Hz]

2500Vrms

Minimum Insulation Resistance [@500 VDC]

10⁹Q

Safety Factor of Load Current

2.5-3 time for resistive load,3-6 times for inductive load

Ambient Operating Temperature Range

-30 to 80℃

Ambient Storage Temperature Range

-30 to 100℃

Humidity per IEC60068-2-78

95%

LED Input Status Indicator

Red

Baseplate Material

Pure copper

Weight

120g


Connection Diagram

Connection diagram

   

Dimensions

Dimensions


Previous: 
Next: 
Feedback

Navigations

Product Categories

Contact Us

   +86-577-61731117
   +86-577-61731116
   +86-13868772123
   +86-13868772123

Get In Touch

Check our privacy policy on how we collect and process your information.
Copyright 2022 © Zhejiang Zonzen Electric Co., Ltd. All Rights Reserved. Sitemap. Privacy Policy