Availability: | |
---|---|
Quantity: | |
VDR
ZONZEN
Product Description
DC solid state relay is mainly used in industrial automation, isolated control of weak current and strong current and various high-power DC electrical equipment, such as DC motors, solenoid valves, electromagnetic vibrators, batteries charge and discharge switch etc.
Ordering options
1. VDR: DC solid state relays
2. Load current: 10: 10Amps, 25: 25Amps, 40: 40Amps, 60: 60Amps, 80: 80Amps, 100: 100Amps, 120: 120Amps
3. Control voltage: D: 3~32VDC
4. Output voltage: D06: 12~60VDC, D08: 12~80VDC, D12: 12~120VDC, D25: 12~250VDC, D40: 12~400VDC, D60: 12~600VDC, D90: 12~900VDC, D120: 12~1200VDC
Product Selection
Control Voltage | Output Voltage | Rated Operational Current | ||||||
10Amps | 25Amps | 40Amps | 60Amps | 80Amps | 100Amps | 120Amps | ||
3 to 32VDC | 60VDC | VDR10DD06 | VDR25DD06 | VDR40DD06 | VDR60DD06 | VDR80DD06 | VDR100DD06 | VDR120DD06 |
3 to 32VDC | 80VDC | VDR10DD08 | VDR25DD08 | VDR40DD08 | VDR60DD08 | VDR80DD08 | VDR100DD08 | VDR120DD08 |
3 to 32VDC | 120VDC | VDR10DD12 | VDR25DD12 | VDR40DD12 | VDR60DD12 | VDR80DD12 | VDR100DD12 | VDR120DD12 |
3 to 32VDC | 250VDC | VDR10DD25 | VDR25DD25 | VDR40DD25 | VDR60DD25 | VDR80DD25 | VDR100DD25 | VDR120DD25 |
3 to 32VDC | 400VDC | VDR10DD40 | VDR25DD40 | VDR40DD40 | VDR60DD40 | VDR80DD40 | VDR100DD40 | VDR120DD40 |
3 to 32VDC | 600VDC | VDR10DD60 | VDR25DD60 | VDR40DD60 | VDR60DD60 | VDR80DD60 | VDR100DD60 | VDR120DD60 |
3 to 32VDC | 900VDC | VDR10DD90 | VDR25DD90 | VDR40DD90 | VDR60DD90 | VDR80DD90 | VDR100DD90 | VDR120DD90 |
3 to 32VDC | 1200VDC | VDR10DD120 | VDR25DD120 | VDR40DD120 | VDR60DD120 | VDR80DD120 | VDR100DD120 | VDR120DD120 |
Technical Parameter
Input | |
Parameter-list | Specification Limits |
Input Parameter | D |
Control Voltage Range | 3 to 32VDC |
nput Current [Max.] | 4-30mA |
Must Turn-on Voltage | 3VDC |
Must Turn-off Voltage | 1VDC |
Reverse Voltage [Max.] | -6VDC |
Output | Units | Specification Limits | ||||||
Load current | Amps | 10 | 25 | 40 | 60 | 80 | 100 | 120 |
Load Current Range | ArmS | 0.05 to 10 | 0.05 to 25 | 0.05 to 40 | 0.1 to 60 | 0.1 to 80 | 0.1 to 100 | 0.1 to 120 |
Surge Current 10mSec [Max.] | Arms | 200% | ||||||
Load Voltage Range | Vrms | 60VDC~1200VDC | ||||||
On-state Voltage drop | Vrms | ≤0.5~4.6 | ||||||
nff-state Voltage | Vrms | 60V,80V,250V,400V600V,≥900V,1200V | ||||||
Overvoltage Protection | Transient protection voltage are :80V,180V,470V,1000V | |||||||
Switching Characteristics | Mos or IGBT-solid-state non-contact switching characteristics |
General Specifications [Ta=25°C] | |||||||
Description | 10A | 25A | 40A | 60A | 80A | 100A | 120A |
Dielectric Strength,Input to Output [50/60 Hz] | 2500Vrms | ||||||
Dielectric Strength,Input/Output to Base [50/60 Hz] | 2500Vrms | ||||||
Minimum Insulation Resistance [@500 VDC] | 10⁹Q | ||||||
Safety Factor of Load Current | 2.5-3 time for resistive load,3-6 times for inductive load | ||||||
Ambient Operating Temperature Range | -30 to 80℃ | ||||||
Ambient Storage Temperature Range | -30 to 100℃ | ||||||
Humidity per IEC60068-2-78 | 95% | ||||||
LED Input Status Indicator | Red | ||||||
Baseplate Material | Pure copper | ||||||
Weight | 120g |
Connection Diagram