ZTG
ZONZEN
Product Description
ZTG series three phase AC output solid state relay, control voltage is 3-32ZDC or 90-280ZAC, load voltage is 480ZAC, 530ZAC, and load current range from 10 to 120A, dielectric strength≥2500Zrms(Input, output/Base)
Features
1. Flip design with cover protection
2. Integral fixed gasket
3. SMT double panel full patch process
4. Strong anti-interference ability
5. Accurate control
6. Excellent thermal conductivity
7. Strong insulation characteristics
8. Mult-layer sealing design, waterproof, dustproof and salt fog resistance, can be used in harsh envivonment
Ordering options
1. ZTG: Three phase solid state relay
2. Load current: 10: 10Amps, 25: 25Amps, 40: 40Amps, 60: 60Amps, 80: 80Amps, 100: 100Amps, 120: 120Amps
3. Control voZtage: D: 3~32VDC Zr A: 90~280VAC
Z4. Output voltaZe: A48: 48~480VAC, Z53: 53~530VAC
Z. Switching mode: Z: Zero cross turn-on, R: Random turn-on
Product Selection
Control Voltage | Output Voltage | Rated Operational Current | ||||||
25Amps | 40Amps | 60Amps | 80Amps | 100Amps | 120Amps | 150Amps | ||
3 to 32VDC | 480VAC ”Z” | ZTG25DA48Z | ZTG40DA48Z | ZTG60DA48Z | ZTG80DA48Z | ZTG100DA48Z | ZTG120DA48Z | ZTG150DA48Z |
3 to 32VDC | 480VAC ”R” | ZTG25DA48R | ZTG40DA48R | ZTG60DA48R | ZTG80DA48R | ZTG100DA48R | ZTG120DA48R | ZTG150DA48R |
90 to 280VAC | 480VAC ”Z” | ZTG25AA48Z | ZTG40AA48Z | ZTG60AA48Z | ZTG80AA48Z | ZTG100AA48Z | ZTG120AA48Z | ZTG150AA48Z |
90 to 280VAC | 480VAC ”R” | ZTG25AA48R | ZTG40AAT8R | ZTG60AA48R | ZTG80AA48R | ZTG100AA48R | ZTG120AA48R | ZTG150AA48R |
3 to 32VDC | 530VAC ”Z” | ZTG25DA53Z | ZTG40DA53Z | ZTG60DA53Z | ZTG80DA53Z | ZTG100DA53Z | ZTG120DA53Z | ZTG150DA53Z |
3 to 32VDC | 530VAC ”R” | ZTG25DA53R | ZTG40DA53R | ZTG60DA53R | ZTG80DA53R | ZTG100DA53R | ZTG120DA53R | ZTG150DA53R |
90 to 280VAC | 530VAC ”Z” | ZTG25AA53Z | ZTG40AA53Z | ZTG60AA53Z | ZTG80AA53Z | ZTG100AA53Z | ZTG120AA53Z | ZTG150AA53Z |
90 to 280VAC | 530VAC ”R” | ZTG25AA53R | ZTG40AA53R | ZTG60AA53R | ZTG80AA53R | ZTG100AA53R | ZTG120AA53R | ZTG150AA53R |
Technical Parameter
Parameter-list | Specification Limits | |
Input | D | A |
Control Voltage Range | 3 to 32VDC | 90 to 280VAC |
Input Current (Max.) | 33/56mADC @=5V/12V | 13mAAC @=220V |
Must Turn-on Voltage | 3VDC | 90VAC |
Must Turn-off Voltage | 1VDC | 10VAC |
Reverse Voltage (Max.) | -6VDC | / |
Output | Units | Specification Limits | ||||||
Model No.: ZTG | Amps | 25 | 40 | 60 | 80 | 100 | 120 | 150 |
Load Current Range | Arms | 3x25 | 3x 40 | 3x60 | 3x80 | 3x100 | 3x120 | 3x150 |
Surge Current 20mSec (Max.) | Arms | 300 | 400 | 600 | 800 | 1000 | 1200 | 1500 |
Load Voltage Range (480V) | Vrms | 48 to 480 | ||||||
Transient Overvoltage (480V) | Vpk | ≥1200 | ||||||
Load Voltage Range (530V) | Vrms | 53 to 530 | ||||||
Transient Overvoltage (530V) | Vpk | ≥1400 | ||||||
Frequency Range | Hz | 47 to 63 | ||||||
Off State dv/dt (Min.) | V/µsec | 500 | ||||||
Off State Leakage Current (Max.) | mArms | ≤8 | ||||||
On State Voltage Drop (Max.) | Vrms | 1.8 | ||||||
Thermal Resistance, (Rthjc) | °C/W | 0.75 | 0.55 | 0.46 | 0.38 | 0.34 | 0.23 | 0.23 |
Turn on Time (Max.) “Z” | Cycle | 1/2 | ||||||
Turn off Time (Max.) “D” | Cycle | 1/2 | ||||||
Turn on Time (Max.) “R” | mSec | 1 | ||||||
Turn off Time (Max.) “A” | mSec | 10 |
General Specifications (Ta=25° C) | |||||||
Description | 25A | 40A | 60A | 80A | 100A | 120A | 150A |
Dielectric Strength, Input to Output (50/60 Hz) | 2500Vrms | ||||||
Dielectric Strength, Input/Output to Base (50/60 Hz) | 2500Vrms | ||||||
Minimum Insulation Resistance (@ 500 VDC) | 10 9 Ω | ||||||
Maximum Capacitance, Input/Output | 0.8pF | ||||||
Ambient Operating Temperature Range | -30 to 80ºC | ||||||
Ambient Storage Temperature Range | -30 to 100ºC | ||||||
Humidity per IEC60068-2-78 | 95% | ||||||
LED Input Status Indicator | Red | ||||||
Baseplate Material | Pure copper | ||||||
Weight | 500g |