Availability: | |
---|---|
Quantity: | |
AVP
ZONZEN
Product Description
AVP series is a single-phase AC solid-state relay,which integrates phase shift trigger circuit, resistance absorption circuit and silicon scr. By adjusting the control signal, changing the voltage on the resistance load to adjust the output power. Can be widely used in lighting equipment lighting adjustment,civil industrial heating temperature control and motor speed control ,plastic suction machine and other occasions.
Ordering options
1. AVP: Single phase AC voltage regulator module
2. Load current: 10: 10Amps, 25: 25Amps, 40: 40Amps, 60: 60Amps, 80: 80Amps, 100: 100Amps, 120: 120Amps
3. Control voltage: G: 4-20mA, F: 2-10Vdc
4. Output voltage: 24: 0~240Vac, 38: 0~380Vac
Product Selection
Control Voltage | Output Voltage | Rated Operational Current | ||||||
10Amps | 25Amps | 40Amps | 60Amps | 80Amps | 100Amps | 120Amps | ||
4-20mA | 0-240VAC | AVP10GV24 | AVP25GV24 | AVP40GV24 | AVP60GV24 | AVP80GV24 | AVP100GV24 | AVP120GV24 |
4-20mA | 0-380VAC | AVP10GV38 | AVP25GV38 | AVP40GV38 | AVP60GV38 | AVP80GV38 | AVP100GV38 | AVP120GV38 |
2-10VDC | 0-240VAC | AVP10FV24 | AVP25FV24 | AVP40FV24 | AVP60FV24 | AVP80FV24 | AVP100FV24 | AVP120FV24 |
2-10VDC | 0-380VAC | AVP10FV38 | AVP25FV38 | AVP40FV38 | AVP60FV38 | AVP8OFV38 | AVP100FV38 | AVP120FV38 |
Specifications
Parameter | Unit | Specification Limits | ||||||
Load Current | Amps | 10 | 25 | 40 | 60 | 80 | 100 | 120 |
Load Current Range | Arms | 0.05 to 10 | 0.05 to 25 | 0.1 to 40 | 0.1 to 60 | 0.1 to 80 | 0.1 to 100 | 0.1 to 120 |
Control Voltage | mA/V | 4-20mA or 2-10VDC | ||||||
Load Voltage Regulation Range | V | 0-240VAC or 0-380VAC | ||||||
Minimum On-current | mA | 50mA | ||||||
Maximum On-state Voltage Drop | Vrms | 2VAC | ||||||
Maximum Off-state Current | mA | 5mA | ||||||
On-off Time | MS | ≤10ms | ||||||
Working Frequency | Hz | ≤45-65Hz | ||||||
Insulation resistance | Mo | 1000M-[500VDC] | ||||||
Dielectric Strength,Input to Output | Vrms | 2500Vrms | ||||||
Dielectric Strength,Input/Output to Base | Vrms | 2500Vrms | ||||||
Ambient Operating Temperature Range | ℃ | -30 to 80℃ |
Connection Diagram
Dimensions