Thermocouple & Thermometer & Thermostat & wk-r11-1

 

 
WK-R11

Product model: WY-R11 “¢ñ” Range of temperauture control: 30¡«85¡æ Rated current: 16A Rated voltage: ¡«250V

Model

Model
Range of temperature control ¡æ(¦ÏF)
Set error
Switch difference
No.of contact-point
WK-R111 ¢ñ
-40¡«+40¡æ
(-40¡«104¦ÏF)
¡À3¡æ
8¡À2¡æ
One pair of N.C.contact
WK-R112 ¢ñ
30¡«85¡æ
(86¡«185¦ÏF)
¡À3¡æ
8¡À2¡æ
WK-R113 ¢ñ
20¡«110¡æ
(68¡«230¦ÏF)
¡À3¡æ
8¡À2¡æ
WK-R114 ¢ñ
100¡«200¡æ
(212¡«392¦ÏF)
¡À8¡æ
8¡À2¡æ
WK-R115 ¢ñ
50¡«300¡æ
(122¡«572¦ÏF)
¡À9¡æ
10¡À3¡æ
Note£ºthe change-over different means the difference between the temperature when the switce breaks and the one when the switch restets to close

Installation diagram
Detail specification form

Model
Range of temperature
Diameter of bulb(mm)
Lengih of capiliary(mm)
Msterials of capillary and bulb
Length of adjustable shaft(mm)
Foot
WK-R111¢ñ
-40¡æ¡«+40¡æ
¦µ6
600
Red copper
20
2
WK-R112¢ñ
30¡æ¡«85¡æ
¦µ6
800
Red copper
20
2
WK-R113¢ñ
20¡æ¡«110¡æ
¦µ6
800
Stainless steel/Red copper
20
2
WK-R114¢ñ
50¡æ¡«200¡æ
¦µ3.7
800
Stainless steel
20
2
WK-R115¢ñ
50¡æ¡«300¡æ
¦µ3/¦µ6
800
Stainless steel
20
2

Explanation£º


1. Regarding the range of temperature ,We can make exactly according to the customer from 0¡æ to 320¡æ.
2. Regarding the length of capillary, We can make exactly according to the customer from 350mm to 2000mm.
3. The materials for capillary and bulb,we use copper when the degree is 100¡æ below,Use stainless steel when degree is 100¡æ above.
4. Regarding the length of adjustable shaft, We can make exactly according to the customer from 0 mm to 35mm.
5. The direction and structure of the terminal,we can make according to to the customer.
6. Main fixed position can be rotated and changed 90 degrees angle according to customer¡¯s request exactly .
7. Every type product that with adjustable shaft can choose a kind of konb and circle.
8. Others scpecial terms ,please contact us for more discussion via e-mail zonzen@zonzen.com.