| 75W Single Output SMPS with PFC Function (SP-75) |
 |
|
Features: |
| |
● Universal
AC input/ full range
● Built-in
active PFC function PF >0.93
● 100%
full load burn-in test
● Protections:
Short circuit/ Over load/ Over voltage
● Built-in
constant current limiting circuit
● LED
indicator for power on
● Fixed
switching frequency at PFC: 67KHz, PWM:134KHz
● 3 years
warranty
● Dimensions:
179*99*33mm(L*W*H) |
Model |
SP-
75-3.3 |
SP-
75-5 |
SP-
75-7.5 |
SP-
75-12 |
SP-
75-13.5 |
SP-
75-15 |
SP-
75-24 |
SP-
75-27 |
SP-
75-48 |
| Output |
DC Voltage |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
24V |
48V |
| Voltage Tolerance |
±2% |
±2% |
±2%% |
±2%% |
±2% |
±2% |
±1% |
±1% |
±1% |
| Rated Current |
15A |
15A |
10A |
6.3A |
5.6A |
5A |
3.2A |
2.8A |
1.6A |
| Current Range |
0-15A |
0-15A |
0-10A |
0-6.3A |
0-5.6A |
0-5A |
0-3.2A |
0-2.8A |
0-1.6A |
| Rated Power |
49.5W |
75W |
75W |
75.6W |
75.6W |
75W |
76.8W |
75.6W |
76.8W |
| Ripple & Noise |
80
mVp-p |
80
mVp-p |
80
mVp-p |
80
mVp-p |
80
mVp-p |
80
mVp-p |
100
mVp-p |
100
mVp-p |
100
mVp-p |
| DC Voltage
Adj. Range |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
Setup,Rise,Hold Time
|
600ms, 60ms, 20ms at full
load |
| Input |
Voltage Range |
85~264
VAC 47-63Hz; 120~370VDC |
| Power Factor |
PF >0.93/230VAC,
PF >0.96/115VAC at full load |
| AC Current |
1.3A/115
VAC 0.7A/230VAC |
| Efficiency |
68% |
72% |
74% |
77% |
78% |
79% |
80% |
80% |
80% |
| Inrush Current |
Cold start
40A/230VAC |
| Leakage Current |
<
2mA/240VAC |
| Protection |
Over Load |
105%~150% |
Protection type: Constant current
limiting, recovers
automatically after fault
condition is removed |
| Over Voltage |
115%~135% |
| Protection type: Shut down
o/p voltage, re-power on to recover |
| Function |
Remote Control(Optional) |
CN3:4
~ 10VDC POWER OFF , <0 ~ 0.8VDC POWER ON |
| Environment |
Working
Temp & Humidity |
-10℃~+60℃;
20%~90 %RH |
| Storage
Temp & Humidity |
-20℃~+85℃;
10%~95 %RH |
| Vibration |
10~500Hz,
2G 10min./1cycle, period for 60min,
each along X, Y, Z axes |
| Safety |
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG:
1.5KVAC O/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:
100MΩ / 500VDC |
| Standards |
Safety Standard |
Design refer to UL1950,TUV EN60950 |
| EMC Standard |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;
ENV50204,EN55024 |
| Others |
Weight |
0.58Kg |
| Packing |
20pcs/12.0Kg/0.64CUFT |
|
|
|
|