| 500W Single Output SMPS with PFC Function (SKSP-500) |
 |
|
Features: |
| |
● High efficiency, high
reliability
● Universal AC
input/ full range
● Built-in
active PFC function, PF >0.93/230VAC
● 100% full load burn-in test
● Protections:
Short circuit/ Over load/ Over voltage/ Over temperature
● Built-in remote ON-OFF control and
remote sense function
● Forced air cooling by built-in DC
fan
● 3 years warranty
● Dimensions:
268*127*50mm(L*W*H) |
Model |
SKSP-
500
-5 |
SKSP-
500
-12 |
SKSP-
500
-13.5 |
SKSP-
500
-15 |
SKSP-
500
-24 |
SKSP-
500
-24 |
SKSP-
500
-48 |
| Output |
DC Voltage(V) |
5V |
12V |
13.5V |
15V |
24V |
24V |
48V |
| Voltage Tolerance |
±2% |
±1.5% |
±1.5% |
±1.5% |
±1% |
±1% |
±1% |
| Rated Current |
85A |
42A |
37A |
34A |
21A |
18.5A |
11A |
| Current Range |
0-85A |
0-42A |
0-37A |
0-34A |
0-21A |
0-18.5A |
0-11A |
| Rated Power |
425W |
504W |
499.5W |
510W |
504W |
499.5W |
528W |
| Ripple & Noise |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
250mVp-p |
DC Voltage
Adj. Range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
Setup,Rise,Hold
Time
|
1000ms,80ms,20ms at full
load |
| Input |
Voltage Range |
90~264VAC(5V: 85~264VAC) 47~63
Hz;
selected by switch 120~370VDC |
| Power Factor |
PF >0.93/230VAC |
| AC Current |
7A/115 VAC3.5A/230VAC |
| Efficiency |
78% |
84% |
84% |
84% |
85% |
85% |
86% |
| Inrush Current |
Cold start 40A /230VAC |
| Leakage Current |
<1.5mA/ 264VAC/60Hz |
| Protection |
Over Load |
110%~130% |
Protection type: Constant current limiting,
recovers automatically
after fault condition is
removed |
| Over Voltage |
110%~130% |
| Protection type: Shut down o/p
voltage, re-power on to recover |
| Over Temp |
When TSW1≥80℃, TSW2≥90℃ |
Protection type: Shut down o/p
voltage, recovers
automatically after temperature goes
down |
| Environment |
Working Temp & Humidity |
-10℃~+60℃; 20%~90 %RH |
| Storage Temp
& Humidity |
-20℃~+85℃; 10%~95 %RH |
| Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min,
each along X, Y, Z axes |
| Safety |
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVAC O/P-FG:
0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100MΩ
/ 500VDC |
| Standards |
Safety Standard |
UL60950-1, EN60950-1 |
| EMC Standard |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;
ENV50204,EN61000-6-2 |
| Others |
Weight |
1.7Kg |
| Packing |
6pcs/11.3Kg/0.67CUFT |
|
|
|
|