| 30W Single Output Industrial Din Rail Power Supply (DR-30) |
 |
|
Features: |
| |
●
Universal AC input/ full range
●
Protections: Short circuit/ Over load/ Over voltage
●
Cooling by free air convection
●
Can be installed on DIN rail TS-35/7.5 or 15
●
Isolation classⅡ
●
LED indicator for power on
●
100% full load burn-in test
● 3
years warranty
● Dimensions:
78*93*56mm (W*H*D) |
Model |
DR-30-5 |
DR-30-12 |
DR-30-15 |
DR-30-24 |
| Output |
DC Voltage |
5V |
12V |
15V |
24V |
| Voltage Tolerance |
±2% |
±1% |
±1% % |
±1% |
| Rated Current |
3A |
2A |
2A |
1.5A |
| Current Range |
0-3A |
0-2A |
0-2A |
0-1.5A |
| Rated Power |
15W |
24W |
30W |
36W |
| Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
| DC Voltage
Adj. Range |
-5%,+10% |
±10% |
±10% |
±10% |
Setup,Rise,
Hold Time |
100ms,30ms/230VAC
100ms,30ms/115VAC at full load |
| Input |
Voltage Range |
85~264 VAC 47~63 Hz; selected by switch
120~370VDC |
| AC Current |
0.88 A/115 V 0.48A/ 230 V |
| Efficiency |
74% |
81% |
81% |
82% |
| Inrush Current |
Cold start 15A/115V 30A/230V |
| Leakage Current |
<
0.5 mA |
| Protection |
Over Load |
105%~160% |
Protection type: Constant current limiting, recovers
automatically after fault condition is removed |
| Over Voltage |
115%~135% |
| Protection type: Shut down o/p voltage, re-power on to recover |
| Environment |
Working Temp & Humidity |
10℃~+60℃; 20%~90 %RH |
| Storage Temp & Humidity |
-20℃~+85℃; 10%~95 %RH |
| Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min,
each along X, Y, Z axes |
| Safety |
Withstand Voltage |
I/P-O/P: 3KVAC |
| Isolation Resistance |
I/P-O/P: 100MΩ / 500VDC |
| Standards |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
| EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3 |
| Others |
Weight |
0.27Kg |