Power Supply Components & switching Power Supply & Standard Series Switching Power Supply & 60W Quad Output Switching Power Suppy (SKQ-60)

 

 
60W Quad Output Switching Power Suppy (SKQ-60)

Features:
 
   High efficiency, high reliability
   Universal AC input/ full range
   Protections: Short circuit/ Over load/ Over voltage
   Cooling by free air convection
   LED indicator for power on
   Fixede switching frequency at 35KHz
   2 years warranty
   Dimensions:: 159*97*38mm(L*W*H)

60W Quad Output Switching Power Suppy (SKQ-60)
Specification:

Model
SKQ-60B
SKQ-60C
SKQ-60D
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH3
CH1
CH2
CH3
CH3
  Output   DC Voltage
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
  Voltage   Tolerance
±2%
±6%
±5%
±5%
±2%
+8 -4 %
±5%
±5%
±2%
±6%
+8 -4 %
±5%
  Rated Current
5.5A
2A
0.5A
0.5A
5.5A
1.5A
0.5A
0.5A
4A
1A
1A
0.5A
  Current Range
0.5-8A
0.1-3A
0-1A
0-1A
0.5-8A
0.1-3A
0-1A
0-1A
0.5-8A
0.1-3A
0.1-1A
0-1A
  Rated Power
60W
60W
62W
  Ripple & Noise
  (mVp-p)
100
mV
120
mV
100
mV
120
mV
100
mV
120
mV
100
mV
120
mV
100
mV
120
mV
150
mV
120
mV
  DC Voltage Adj. Range    CH1: -5%, +10%
  Setup,Rise,Hold   Time
   1600ms,20ms,12ms/115VAC      
   800ms,20ms, 60ms/230VAC at full load
  Input   Voltage Range    85~264 VAC 47-63Hz; 120~370VDC
  AC Current    2A/115V 0.8A/ 230 V
  Efficiency
70%
72%
75%
  Inrush Current    Cold start 18A/115V36A/230V
  Leakage Current    < 1 mA/240VAC
  Protection   Over Load    105%~150% /115VAC
   Protection type: Shut down o/p voltage, recovers
   automatically after fault condition is removed
  Over Voltage    5V: 115%~135%
   Protection type: Hiccup mode, recovers
   automatically after fault condition is removed
  Environment   Working Temp   &   Humidity    -10℃~+60℃; 20%~90 %RH
  Storage Temp   & Humidity    -20℃~+85℃; 10%~95 %RH
  Vibration    10~500Hz, 2G 10min./1cycle, period for 60min,
   each along X, Y, Z axes
  Safety   Withstand   Voltage    I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
  Isolation   Resistance    I/P-O/P, I/P-FG, O/P-FG: 100MΩ/500VDC
  Standards   Safety Standard    Design refer to UL60950
  EMC Standard    Design refer to EN55022,EN61000-3-2,-3,
   EN61000-4-2,3,4,5,6,8,11; ENV50204
  Others   Weight    0.56Kg
  Packing    30pcs/17Kg/0.86CUFT