Power Supply Components & switching Power Supply & PFC Series Switching Power Supply & 100W Single Output SMPS with PFC Function (SP-100)

 

 
100W Single Output SMPS with PFC Function (SP-100)

Features:
 
●  Universal AC input/ full range
  Built-in active PFC function PF>0.93
  100% full load burn-in test
●  Protections: Short circuit/ Over load/ Over voltage
  Built-in constant current limiting circuit
  LED indicator for power on
  Remote ON-OFF control (Optional)
  Fixed switching frequency at PFC: 67KHz   PWM:134KHz
●  3 years warranty
  Dimensions: 179*99*45mm(L*W*H)

100W Single Output SMPS with PFC Function (SP-100)
Model
SP-
100
-3.3
SP-
100
-5
SP-
100
-7.5
SP-
100
-12
SP-
100-13.5
SP-
100
-15
SP-
100
-24
SP-
100
-27
SP-
100
-48
  Output   DC Voltage(V)
3.3V
5V
7.5V
12V
13.5V
15V
24V
24V
48V
  Voltage Tolerance
±2%
±2%
±2%%
±2%%
±2%
±2%
±1%
±1%
±1%
  Rated Current
20A
20A
13.5A
8.5A
7.5A
6.7A
4.2A
3.8A
2.1A
  Current Range (A)
0-20
0-20
0-13.5
0-8.5
0-7.5
0-6.7
0-4.2
0-3.8
0-2.1
  Rated Power (W)
66
100
101.25
102
101.25
100.5
100.8
102.6
100.8
  Ripple & Noise (mVp-p)
80
80
80
80
80
80
100
100
100
  DC Voltage  
  Adj. Range
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
-5%
+10%
  Setup,Rise,Hold Time
  600ms,30ms,20ms at full lod
  Input   Voltage Range   85~264 VAC 47-63Hz; 120~370VDC
  Power Factor   PF >0.93/230VAC, PF >0.98/115VAC at full load
  AC Current   1.7A/115 VAC 0.8A/230VAC
  Efficiency
70%
76%
78%
80%
80%
82%
84%
83%
82%
  Inrush Current   Cold start 40A/230VAC
  Leakage Current   < 2mA/240VAC
  Protection   Over Load   105%~150%
  Protection type: Constant current limiting, recovers
  automatically after fault condition is removed
  Over Voltage   115%~135%
  Protection type: Shut down o/p voltage,
  re-power on to recover
  Function   Remote Control
  (Optional)
  CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
  Environment   Working Temp & Humidity   -10℃~+60℃; 20%~90 %RH
  Storage Temp & Humidity   -20℃~+85℃; 10%~95 %RH
  Vibration   10~500Hz, 2G 10min./1cycle, period for 60min,
  each along X, Y, Z axes
  Safety   Withstand Voltage   I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
  Isolation Resistance   I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC
  Standards   Safety Standard   Design refer to UL1950,TUV EN60950
  EMC Standard   EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;
  ENV50204,EN55024
  Others   Weight   0.6Kg
  Packing   20pcs/12.0Kg/1.17CUFT