| 100W Single Output SMPS with PFC Function (SP-100) |
 |
|
Features: |
| |
● Universal AC input/ full
range
● Built-in
active PFC function PF>0.93
● 100%
full load burn-in test
● Protections: Short circuit/ Over
load/ Over voltage
● Built-in
constant current limiting circuit
● LED
indicator for power on
● Remote
ON-OFF control (Optional)
● Fixed
switching frequency at PFC: 67KHz PWM:134KHz
● 3
years warranty
● Dimensions:
179*99*45mm(L*W*H) |
Model |
SP-
100
-3.3 |
SP-
100
-5 |
SP-
100
-7.5 |
SP-
100
-12 |
SP-
100-13.5 |
SP-
100
-15 |
SP-
100
-24 |
SP-
100
-27 |
SP-
100
-48 |
| Output |
DC Voltage(V) |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
24V |
48V |
| Voltage Tolerance |
±2% |
±2% |
±2%% |
±2%% |
±2% |
±2% |
±1% |
±1% |
±1% |
| Rated Current |
20A |
20A |
13.5A |
8.5A |
7.5A |
6.7A |
4.2A |
3.8A |
2.1A |
| Current Range (A) |
0-20 |
0-20 |
0-13.5 |
0-8.5 |
0-7.5 |
0-6.7 |
0-4.2 |
0-3.8 |
0-2.1 |
| Rated Power (W) |
66
|
100
|
101.25
|
102
|
101.25 |
100.5 |
100.8 |
102.6 |
100.8 |
| Ripple & Noise (mVp-p) |
80
|
80
|
80
|
80
|
80 |
80 |
100 |
100 |
100 |
DC Voltage
Adj. Range |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
-5%
+10% |
Setup,Rise,Hold
Time
|
600ms,30ms,20ms at full lod |
| Input |
Voltage Range |
85~264 VAC 47-63Hz; 120~370VDC |
| Power Factor |
PF >0.93/230VAC, PF >0.98/115VAC at full load |
| AC Current |
1.7A/115 VAC 0.8A/230VAC |
| Efficiency |
70% |
76% |
78% |
80% |
80% |
82% |
84% |
83% |
82% |
| Inrush Current |
Cold start 40A/230VAC |
| Leakage Current |
<
2mA/240VAC |
| Protection |
Over Load |
105%~150% |
Protection type: Constant current
limiting, recovers
automatically after fault
condition is removed |
| Over Voltage |
115%~135% |
Protection type: Shut down
o/p voltage,
re-power on to recover |
| Function |
Remote Control
(Optional) |
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER
OFF |
| Environment |
Working
Temp & Humidity |
-10℃~+60℃;
20%~90 %RH |
| Storage
Temp & Humidity |
-20℃~+85℃;
10%~95 %RH |
| Vibration |
10~500Hz,
2G 10min./1cycle, period for 60min,
each along X, Y, Z axes |
| Safety |
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG:
0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:
100MΩ / 500VDC |
| Standards |
Safety Standard |
Design refer to UL1950,TUV EN60950 |
| EMC Standard |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;
ENV50204,EN55024 |
| Others |
Weight |
0.6Kg |
| Packing |
20pcs/12.0Kg/1.17CUFT |
|
|
|
|