Thermocouple & Thermometer & Mineral insulated cable & MI thermocouple cable

 

 
MI thermocouple cable

Feature :
1). Mineral insulated cables are the industry standard, proven choice for high temperature probe fabrication.
2). Bulk MI cable is rugged, inexpensive, reliable, widely accepted by industry, and readily available in standard configurations,
the metal sheath provides a self-armoured cable, which is mechanically robust even at small diameters.
3). The small mass and high thermal conductivity of a properly made cable promotes rapid response of the finished thermocouple assembly.
4). Sheath materials can be selected to offer strong resistance against corrosive environments and extremely high temperature
effects.

Sheath Specification:

Sheath Material

Nominal Chemical Composition (% weight)

Continuous Max. Temp.

Melting Temp.

Application Notes

Fe

Ni

Cr

C

Mo

Mn

S

Si

Cu

Tensile

 

 

 

Max

 

Max

Max

Max

0.1

(1000 psi)

304

Bal

10

19

0.03

 

2

0.03

1

0.1

80

900¡ãC

1400¡ãC

Good resistance to corrosion and oxidation

316

Bal

12

17

0.03

2

2

0.03

1

0.1

85

925¡ãC

1370¡ãC

Good corrosion resistance and creep strength at elevated temperatures (Mo). Resists tendency to pit in phosphoric and aetic acids. Withstands sulphuric acid compounds.

316L

Bal

12

17

0.03

2

2

0.03

1

0.1

80

925¡ãC

1370¡ãC

Good corrosion resistance and creep strength at elevated temperatures (Mo). Resists tendency to pit in phosphoric and aetic acids. Withstands sulphuric acid compounds.

310S

Bal

20

25

0.08

 

2

0.03

1.5

0.1

100

1100¡ãC

1400¡ãC

High temperature strength and scale resistance. Good resistance to carburising and reducing envirnoments. Withstands sulphurous gas at elevated temperatures (high Ni-Cr)

INC600

bal

76

16

0.04

 

0.2

0.01

0.2

0.1

90

1150¡ãC

1400¡ãC

High corrision resistance at elevated temperatures. High hot strength. Used in sulphur-free environments. Resists oxidising and reducing atmospheres.



Sheath OD
(mm)

Wall thickness (mm)

Wire dia.
(mm)

Length
(m/roll)

Sheath material

Tolerance

Calibration

Limits

Temp. Range
¡ãC

1.6

0.16-0.26

0.26-0.36

200

SUS304
SUS316
SUS316L
SUS310L
INC600

K

1.5¡ãC or 0.4%t

-40~1000

2.0

0.25-0.35

0.40-0.50

180

3.0

0.38-0.48

0.50-0.60

80

J

-40~750

3.2

0.48-0.58

0.58-0.68

75

4.0

0.52-0.62

0.60-0.70

70

E

-40~800

4.8

0.73-0.83

0.75-0.85

40

6.0

0.98-1.08

0.90-1.10

30

T

0.5¡ãC or 0.4%t

-40~350

8.0

1.30-1.44

1.30-1.40

20


Order No.

Calibration (Order No.)

Sheath OD (mm)

Sheath Material

Type K

Type J

Type E

Type T

MIC-K-¦Õ1.6-304

MIC-J-¦Õ1.6-304

MIC-E-¦Õ1.6-304

MIC-T-¦Õ1.6-304

1.6

304

MIC-K-¦Õ1.6-316

MIC-J-¦Õ1.6-316

MIC-E-¦Õ1.6-316

MIC-T-¦Õ1.6-316

1.6

316

MIC-K-¦Õ1.6-316L

MIC-J-¦Õ1.6-316L

MIC-E-¦Õ1.6-316L

MIC-T-¦Õ1.6-316L

1.6

316L

MIC-K-¦Õ1.6-310S

-

-

-

1.6

310S

MIC-K-¦Õ1.6-INC600

-

-

-

1.6

INC600

MIC-K-¦Õ2-304

MIC-J-¦Õ2-304

MIC-E-¦Õ2-304

MIC-T-¦Õ2-304

2

304

MIC-K-¦Õ2-316

MIC-J-¦Õ2-316

MIC-E-¦Õ2-316

MIC-T-¦Õ2-316

2

316

MIC-K-¦Õ2-316L

MIC-J-¦Õ2-316L

MIC-E-¦Õ2-316L

MIC-T-¦Õ2-316L

2

316L

MIC-K-¦Õ2-310S

-

-

-

2

310S

MIC-K-¦Õ2-INC600

-

-

-

2

INC600

MIC-K-¦Õ3-304

MIC-J-¦Õ3-304

MIC-E-¦Õ3-304

MIC-T-¦Õ3-304

3

304

MIC-K-¦Õ3-316

MIC-J-¦Õ3-316

MIC-E-¦Õ3-316

MIC-T-¦Õ3-316

3

316

MIC-K-¦Õ3-316L

MIC-J-¦Õ3-316L

MIC-E-¦Õ3-316L

MIC-T-¦Õ3-316L

3

316L

MIC-K-¦Õ3-310S

-

-

-

3

310S

MIC-K-¦Õ3-INC600

-

-

-

3

INC600

MIC-K-¦Õ3.2-304

MIC-J-¦Õ3.2-304

MIC-E-¦Õ3.2-304

MIC-T-¦Õ3.2-304

3.2

304

MIC-K-¦Õ3.2-316

MIC-J-¦Õ3.2-316

MIC-E-¦Õ3.2-316

MIC-T-¦Õ3.2-316

3.2

316

MIC-K-¦Õ3.2-316L

MIC-J-¦Õ3.2-316L

MIC-E-¦Õ3.2-316L

MIC-T-¦Õ3.2-316L

3.2

316L

MIC-K-¦Õ3.2-310S

-

-

-

3.2

310S

MIC-K-¦Õ3.2-INC600

-

-

-

3.2

INC600

MIC-K-¦Õ4.8-304

MIC-J-¦Õ4.8-304

MIC-E-¦Õ4.8-304

MIC-T-¦Õ4.8-304

4.8

304

MIC-K-¦Õ4.8-316

MIC-J-¦Õ4.8-316

MIC-E-¦Õ4.8-316

MIC-T-¦Õ4.8-316

4.8

316

MIC-K-¦Õ4.8-316L

MIC-J-¦Õ4.8-316L

MIC-E-¦Õ4.8-316L

MIC-T-¦Õ4.8-316L

4.8

316L

MIC-K-¦Õ4.8-310S

-

-

-

4.8

310S

MIC-K-¦Õ4.8-INC600

-

-

-

4.8

INC600

MIC-K-¦Õ6.0-304

MIC-J-¦Õ6.0-304

MIC-E-¦Õ6.0-304

MIC-T-¦Õ6.0-304

6.0

304

MIC-K-¦Õ6.0-316

MIC-J-¦Õ6.0-316

MIC-E-¦Õ6.0-316

MIC-T-¦Õ6.0-316

6.0

316

MIC-K-¦Õ6.0-316L

MIC-J-¦Õ6.0-316L

MIC-E-¦Õ6.0-316L

MIC-T-¦Õ6.0-316L

6.0

316L

MIC-K-¦Õ6.0-310S

-

-

-

6.0

310S

MIC-K-¦Õ6.0-INC600

-

-

-

6.0

INC600

MIC-K-¦Õ6.4-304

MIC-J-¦Õ6.4-304

MIC-E-¦Õ6.4-304

MIC-T-¦Õ6.4-304

6.4

304

MIC-K-¦Õ6.4-316

MIC-J-¦Õ6.4-316

MIC-E-¦Õ6.4-316

MIC-T-¦Õ6.4-316

6.4

316

MIC-K-¦Õ6.4-316L

MIC-J-¦Õ6.4-316L

MIC-E-¦Õ6.4-316L

MIC-T-¦Õ6.4-316L

6.4

316L

MIC-K-¦Õ6.4-310S

-

-

-

6.4

310S

MIC-K-¦Õ6.4-INC600

-

-

-

6.4

INC600

MIC-K-¦Õ8.0-304

MIC-J-¦Õ8.0-304

MIC-E-¦Õ8.0-304

MIC-T-¦Õ8.0-304

8.0

304

MIC-K-¦Õ8.0-316

MIC-J-¦Õ8.0-316

MIC-E-¦Õ8.0-316

MIC-T-¦Õ8.0-316

8.0

316

MIC-K-¦Õ8.0-316L

MIC-J-¦Õ8.0-316L

MIC-E-¦Õ8.0-316L

MIC-T-¦Õ8.0-316L

8.0

316L

MIC-K-¦Õ8.0-310S

-

-

-

8.0

310S

MIC-K-¦Õ8.0-INC600

-

-

-

8.0

INC600


Order example:
1. MIC-K-¦Õ3.0-316, It means you order MI thermocouple cable is Simplex, type K, sheath dia: 3.0mm, sheath material: SUS316
2. If you order MI thermocouple cable is Duplex, please change ¡°MIC¡± to ¡°MICD¡±, it means ¡°MICD-K-¦Õ3.0-316¡±
3. If you order MI thermocouple cable is Triplex, please change ¡°MIC¡± to ¡°MICT¡±, it means ¡°MICT-K-¦Õ3.0-316¡±