  • Silicone rubber insulated thermocouple extension wire with stainless steel inner shield--Single pair, round
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Conductor Insulation: PFA
    . Inner shield: Stainless steel
    . Jacket insulation: Silicone rubber
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 180°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • Silicone rubber insulated thermocouple extension wire with stainless steel overbraid--Single pair, round
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Conductor insulation: Silicone rubber
    . Jacket insulation: Silicone rubber
    . Outer shield: Stainless steel
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 180°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • Silicone rubber insulated thermocouple extension wire--Single pair, round
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: Silicone rubber
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 180°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • KAPTON insulated thermocouple extension wire with stainless steel overbraid--Double pair, twisted
    . Fused kapton tape applied to conductor and jacket
    . Thermocouple extension wire type JX, KX, TX, EX, NX
    . Kapton wire is not color-coded
    . Excellent moisture & abrasion resistance
    . High dielectric strength
    Add to Basket
  • KAPTON insulated thermocouple wire and thermocouple extension wire--Single pair, flat
    . Fused kapton tape applied to conductor and jacket
    . Thermocouple wire type J, K, T, E, N
    . Thermocouple extension wire type JX, KX, TX, EX, NX
    . Kapton wire is not color-coded
    . Excellent moisture & abrasion resistance
    . High dielectric strength
    Add to Basket
  • PFA insulated twisted pair thermocouple extension wire
    . Calibration: Type KX, JX, EX, TX, NX and RX/SX
    . Conductor: Solid or stranded
    . No. of pair: Single
    . Insulation: PFA
    . Jacket: PFA
    . Construction: Twisted conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 260°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • PFA insulated thermocouple extension wire--Transparent jacket
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: PFA
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error or special limits of error
    . Max. operating temperature: 260°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • PFA insulated thermocouple wire with stainless steel overbraid--Single pair, flat
    . Available in thermocouple type K, J, T, E and N
    . Conductors are extruded with PFA and laid parallel
    . Choice of wire gauge 16, 18, 20, 24, 26, 28, 30AWG
    . Continuous use up to 260 °C
    . Colors available on request.
    . Packing and spool length as required
    Add to Basket
  • PFA insulated thermocouple wire--Single pair, twisted
    . Conductors: Type K, J, E, T, N
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: PFA
    . Construction: Twisted conductor
    . Tolerance: Standard limits of error or special limits of error
    . Max. operating temperature: 260°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • PFA insulated thermocouple extension wire with stainless steel inner shield--Single pair
    . High quality type KX, JX, TX, EX, NX thermocouple extension grade wire
    . Conductors are extruded with PFA
    . Choice of wire gauge 16, 18, 20, 24, 26, 28, 30AWG
    . Continuous use up to 260 °C
    . Colors available on request.
    . Packing and spool length as required
    Add to Basket
  • PFA insulated thermocouple wire--Single pair, flat
    . Conductors: Type K, J, E, T, N
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: PFA
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error or special limits of error
    . Max. operating temperature: 260°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • PFA insulated thermocouple extension wire--Single pair, flat
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: PFA
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error or special limits of error
    . Max. operating temperature: 260°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • FEP insulated thermocouple extension wire with drain and stainless steel inner shield
    . Conductors: Type KX
    . Wire type: Stranded
    . No. of pair: Single
    . Insulation: FEP
    . With tinned copper drain wire
    . Inner shield: Stainless steel
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error
    . Max. operating temperature: 200°C
    . Color code: ANSI
    Add to Basket
  • FEP insulated thermocouple extension wire--Single pair, twisted
    . Conductors: Type KX, JX, EX, TX, NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: FEP
    . Construction: Twisted conductor
    . Tolerance: Standard limits of error or special limits of error
    . Max. operating temperature: 200°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • FEP insulated thermocouple extension wire with stainless steel inner shield--Single pair, flat
    . High quality type KX, JX, TX, EX, NX thermocouple extension grade wire
    . Conductors are extruded with FEP and laid parallel
    . Choice of wire gauge 16, 18, 20, 24, 26, 28, 30AWG
    . Continuous use up to 200 °C
    . Colors available on request.
    . Packing and spool length as required
    Add to Basket
  • FEP insulated thermocouple wire with stainless steel overbraid--Single pair, flat
    . Available in thermocouple type K, J, T, E and N
    . Conductors are extruded with FEP and laid parallel
    . Choice of wire gauge 16, 18, 20, 24, 26, 28, 30AWG
    . Continuous use up to 200 °C
    . Colors available on request.
    . Packing and spool length as required
    Add to Basket
  • Stainless steel braided PVC insulated thermocouple wire and thermocouple extension wire
    . Conductors: Type K/KX, J/JX, E/EX, T/TX, N/NX and RX, SX
    . Wire type: Solid or stranded
    . No. of pair: Single
    . Insulation: PVC
    . Outer shield: Stainless steel braided or tinned copper braided
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 105°C
    . Color code: ANSI, IEC, JIS, DIN
    Add to Basket
  • Fiberglass insulated thermocouple wire and thermocouple extension wire-- Single pair, Flat
    . Calibration: Type K/KX, J/JX, E/EX, T/TX, N/NX and RX, SX
    . Conductor: Solid or stranded
    . No. of pair: Single
    . Insulation: Braided fiberglass with silicon varnish coated
    . Construction: Parallel conductor
    . Overbraid: Stainless steel or tinned copper
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 480°C
    . Color code: ANSI, IEC, JIS, DIN, BS, NFC
    Add to Basket
  • High temperature fiberglass insulated with metal overbraid thermocouple extension wire
    . Calibration: Type K/KX, J/JX, E/EX, T/TX, N/NX and RX, SX, BX
    . Conductor: Solid or stranded
    . No. of pair: Single
    . Insulation: High temperature fiberglass braided with silicon varnish coated
    . Shield: Stainless steel braided (SSB) or Tinned copper braided (TCB)
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 704°C
    . Color code: ANSI, IEC, JIS, DIN, BS, NFC
    Add to Basket
  • Ceramic fiberglass insulated thermocouple wire and thermocouple extension wire
    . Calibration: Type K/KX, J/JX, E/EX, T/TX, N/NX and RX/SX
    . Conductor: Solid or stranded
    . No. of pair: Single
    . Insulation: Ceramic fiberglass
    . Jacket: Ceramic fiberglass
    . Construction: Parallel conductor
    . Tolerance: Standard limits of error and special limits of error
    . Max. operating temperature: 1204°C