You are here: Home » Products » Thermocouple Wire » Silicone rubber insulated thermocouple wire » Stainless steel braid Silicone rubber insulated parallel construction thermocouple extension wire-Single pair, round

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Stainless steel braid Silicone rubber insulated parallel construction thermocouple extension wire-Single pair, round

. Calibration: Type KX, JX, EX, TX, NX and RX, SX
. Wire type: Solid or stranded
. Number of pairs: Single
. Conductor insulation: Silicone rubber
. Jacket insulation: Silicone rubber
. Outer shield: Stainless steel
. Construction: Parallel conductor
. Tolerance: Standard limits of error and special limits of error
. Max. operating temperature: 180°C
. Color code: ANSI, IEC, JIS, DIN
Quantity:

Feature

Stainless steel braid Silicone rubber insulated parallel construction thermocouple extension wire-Single pair, round

. Continuous use up to 180°C
. Short term use up to 250°C
. Good electrical and mechanical properties
. Good flame retardance and moisture resistance

Silicone rubber Physical Properties
Characteristics Insulation Jacket
Abrasion Resistance Excellent Excellent
Flexibility Excellent Excellent
Moisture Resistance Good Good
Weatherability Excellent Excellent
Service Temperature

180°C continuous

250°C single

180°C continuous

250°C single

Flame Test Self-extinguishing Self-extinguishing

Specification

Item Specification
Calibration Type JX Type KX Type TX Type EX Type NX Type RX/SX Type BX
+ Iron
- Constantan
+ Chromel
- Alumel
+ Copper
- Constantan
+ Chromel
- Constantan
+ Nirosil
- Nisil
+ Copper
- Alloy 11
+ Copper-S
- Copper-E
Wire size 20, 24, 26, 28, 30AWG
Wire type Solid or Stranded
Construction Parallel conductors
Number of pair Single
Conductor insulation Silicone rubber
Jacket insulation Silicone rubber
Outer shield Stainless steel
Tolerance Standard limits of error or special limits of error
Max. Operating temperature 180°C
Color code ANSI, IEC, JIS, DIN, BS, NFC
Packing Roll or spool (As required)

Order Code

Model explanation

QQ截图20181116160715
 

1  Calibration: KX, JX, TX, EX, NX, SX, RX, BX
2  Conductor insulation: Silicone rubber
3  Jacket insulation: Silicone rubber
4  Outer shield: Stainless steel
5  Wire size: 20, 24, 26, 28, 30AWG
6  "S" means "Stranded"; "Blank" means "Solid"

Order code:

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Extension wire

20

1/0.80

Solid

JX-SIL-SIL-SSB-20

KX-SIL-SIL-SSB-20

TX-SIL-SIL-SSB-20

EX-SIL-SIL-SSB-20

20 7/28

7/0.30

Stranded

JX-SIL-SIL-SSB-20S

KX-SIL-SIL-SSB-20S

TX-SIL-SIL-SSB-20S

EX-SIL-SIL-SSB-20S

24

1/0.50

Solid

JX-SIL-SIL-SSB-24

KX-SIL-SIL-SSB-24

TX-SIL-SIL-SSB-24

EX-SIL-SIL-SSB-24

24 7/32

7/0.20

Stranded

JX-SIL-SIL-SSB-24S

KX-SIL-SIL-SSB-24S

TX-SIL-SIL-SSB-24S

EX-SIL-SIL-SSB-24S

26 1/0.40 Solid JX-SIL-SIL-SSB-26 KX-SIL-SIL-SSB-26 TX-SIL-SIL-SSB-26 EX-SIL-SIL-SSB-26
26 7/34 7/0.16 Stranded JX-SIL-SIL-SSB-26S KX-SIL-SIL-SSB-26S TX-SIL-SIL-SSB-26S EX-SIL-SIL-SSB-26S
28 1/0.32 Solid JX-SIL-SIL-SSB-28 KX-SIL-SIL-SSB-28 TX-SIL-SIL-SSB-28 EX-SIL-SIL-SSB-28
28 7/36 7/0.13 Stranded JX-SIL-SIL-SSB-28S KX-SIL-SIL-SSB-28S TX-SIL-SIL-SSB-28S EX-SIL-SIL-SSB-28S
30 1/0.25 Solid JX-SIL-SIL-SSB-30 KX-SIL-SIL-SSB-30 TX-SIL-SIL-SSB-30 EX-SIL-SIL-SSB-30

Note: The products referenced above represent the most popular constructions. Other constructions can be manufactured to meet individual specification and application requirements.

Technical Data

Color Code & Initial Calibration Tolerance for Thermocouple Extension Wire:

Thermocouple extension type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron (+) vs.  Constantan(-)

JX

White/Red

Black

0°C to +200°C

± 2.2°C

± 1.1°C

Chromel (+) vs.  Alumel (-)

KX

Yellow/Red

Yellow

0°C to +200°C

± 2.2°C

± 1.1°C

Copper(+) vs. Constantan(-)

TX

Blue/Red

Blue

-60°C to +100°C

± 1.1°C

± 0.5°C

Chromel(+) vs. Constantan(-)

EX

Purple/Red

Purple

0°C to +200°C

± 1.7°C

± 1.1°C

Nirosil (+) vs. Nisil (-) NX Orange/Red Orange 0°C to +200°C ± 2.2°C ± 1.1°C
Copper (+) vs. Alloy 11 (-) RX/SX Black/Red Green 0°C to +200°C ± 5°C -
Copper S (+) vs. -Copper E (-) BX Gray/Red Gray 0°C to +200°C ± 3.7°C -

Nominal Insulation Thickness:

Wire Size (AWG)

Conductor Insulation Thickness (mm)

Jacket Insulation Thickness (mm)

Outer Diameter (mm)

20

0.40

0.80

6±0.20

20 7/28

0.40

0.80

6±0.20

24

0.40

0.80

5.2±0.20

24 7/32

0.40

0.80

5.2±0.20

26 0.35 0.80 4.8±0.20
28 0.35 0.80 4.8±0.20
30 0.35 0.80 4.2±0.20

Previous: 
Next: 
Feedback

Navigations

Product Categories

Contact Us

   +86-577-61731117
   +86-577-61731116
   +86-13868772123
   +86-13868772123

Get In Touch

Check our privacy policy on how we collect and process your information.
Copyright 2022 © Zhejiang Zonzen Electric Co., Ltd. All Rights Reserved. Sitemap. Privacy Policy